Calculation of Consumption and Expenditures for Electricity Energy Costs at Lido Graha Hotel Lhokseumawe City Based on Electrical Power Measurement
DOI:
https://doi.org/10.25008/bcsee.v1i2.1124Keywords:
Energy audit, Building hotel, Electrical energy, Electricity consumptionAbstract
Evaluation of energy utilization and identification become energy saving opportunities, as well as recommendations for increasing efficiency, on energy use and use of energy sources in the context of energy conservation This paper aims to describe the audit of electrical energy in the Lido Graha Lhokseumawe Hotel room, by taking samples in different room types and conducting an electrical energy audit on the use of installed lights and air conditioners. The method used in this study is data collection, interviews, observations and direct measurements on the use of lights and AC (Air Conditioning). The data analysis technique used is to determine the estimated value of electricity consumption and how much it will cost for electricity. From the results of calculations and analysis obtained total electricity consumption needs based on the type of room with various types of loads used 855.62 kWh/days with costs that must be spent per day is Rp. 1,190,574.96, 25,668.6 kWh/month with a monthly cost of Rp. 35,087,608.60. Whereas for a year electricity demand is 308,494.8 kWh/year with a cost of Rp. 421,051,305.24.
Downloads
References
Y. Narangajavana and B. Hu, "The relationship between the hotel rating system, service quality improvement, and hotel performance changes: A canonical analysis of hotels in Thailand," J. Qual. Assur. Hosp. Tour., vol. 9, no. 1, pp. 34-56, 2008. https://doi.org/10.1080/15280080802108259
A. Marzuki and others, "Audit Energi pada Bangunan Gedung Direksi PT. Perkebunan Nusantara XIII (Persero)," 2013.
J. R. Galvão, S. A. Leitão, S. M. Silva, and T. M. Gaio, "Cogeneration supply by bio-energy for a sustainable hotel building management system," Fuel Process. Technol., vol. 92, no. 2, pp. 284-289, 2011. https://doi.org/10.1016/j.fuproc.2010.03.002
Y. Zhu and H. Adler, "Chinese Hotel General Managers' Perspectives on Energy Saving Practices," 2011.
J. Xing, P. Ren, and J. Ling, "Analysis of energy efficiency retrofit scheme for hotel buildings using eQuest software: A case study from Tianjin, China," Energy Build., vol. 87, pp. 14-24, 2015. https://doi.org/10.1016/j.enbuild.2014.10.045
P. Bohdanowicz, A. Churie-Kallhauge, I. Martinac, and D. Rezachek, "Energy-efficiency and conservation in hotels--towards sustainable tourism," 4oSimpósio Int. em Arquitetura da Ásia e Pac{'i}fico, Hava{'i}, 2001.
F. Fazelpour, N. Soltani, and M. A. Rosen, "Feasibility of satisfying electrical energy needs with hybrid systems for a medium-size hotel on Kish Island, Iran," Energy, vol. 73, pp. 856-865, 2014. https://doi.org/10.1016/j.energy.2014.06.097
Ó. Garc'ia, R. S. Alonso, D. I. Tapia, and J. M. Corchado, "Electrical power consumption monitoring in hotels using the n-Core Platform," in 2016 Clemson University Power Systems Conference (PSC), 2016, pp. 1-6.
E. R. Mauboy and others, "Audit Energi Listrik pada Hotel Sotis Kupang," Media Elektro, pp. 149-154, 2019.
S. Önüt and S. Soner, "Energy efficiency assessment for the Antalya Region hotels in Turkey," Energy Build., vol. 38, no. 8, pp. 964-971, 2006. https://doi.org/10.1016/j.enbuild.2005.11.006
J. Guan and K. Chen, "Modeling the relative efficiency of national innovation systems," Res. Policy, vol. 41, no. 1, pp. 102-115, 2012. https://doi.org/10.1016/j.respol.2011.07.001
A. Fraser, B. Delaney, and P. Moayyedi, "Symptom-based outcome measures for dyspepsia and GERD trials: a systematic review," Am. J. Gastroenterol., vol. 100, no. 2, pp. 442-452, 2005. https://doi.org/10.1111/j.1572-0241.2005.40122.x
K. N. Barker, "Data collection techniques: observation," Am. J. Hosp. Pharm., vol. 37, no. 9, pp. 1235-1245, 1980. https://doi.org/10.1093/ajhp/37.9.1235
G. Michailidis and J. De Leeuw, "The Gifi system of descriptive multivariate analysis," Stat. Sci., pp. 307-336, 1998. https://doi.org/10.1214/ss/1028905828
A. W. Hafner, Descriptive statistical techniques for librarians. ERIC, 1998.
F. W. H. Yik, J. Burnett, and I. Prescott, "Predicting air-conditioning energy consumption of a group of buildings using different heat rejection methods," Energy Build., vol. 33, no. 2, pp. 151-166, 2001. https://doi.org/10.1016/S0378-7788(00)00094-3
I. Knight, S. Stravoravdis, and S. Lasvaux, "Predicting operational energy consumption profiles-Findings from detailed surveys and modelling in a UK educational building compared to measured consumption," Int. J. Vent., vol. 7, no. 1, pp. 49-57, 2008. https://doi.org/10.1080/14733315.2008.11683798
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2020 Arnawan Hasibuan, Widyana Verawaty Siregar, Elvy Sahnur Nasution, Rohana Ismail

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.