Modification of the Automatic Control System for Arduino ATmega 328P-Based Water Gallon Cleaner

Authors

  • Kharisma Ramadhan Department of Electrical Engineering, Gajah Tunggal Polytechnic, Indonesia
  • Lutfi Hinda Mukti Department of Electrical Engineering, Gajah Tunggal Polytechnic, Indonesia
  • M. Raghib Alashbahanni Mahfudz Department of Electrical Engineering, Gajah Tunggal Polytechnic, Indonesia
  • M. Dafa Dezan Rezaputra Department of Electrical Engineering, Gajah Tunggal Polytechnic, Indonesia
  • M. Taufiqul Hafizh Department of Electrical Engineering, Gajah Tunggal Polytechnic, Indonesia

DOI:

https://doi.org/10.25008/bcsee.v2i2.1131

Keywords:

Electrical Engineering, Modication, Arduino ATmega 328P, Ultrasonic Sensor HC-SR04, Automatic Control System , arduino, IoT

Abstract

Humans are living things that have 60 trillion cells to build the body, each cell of the human body contains 70% more water. Humans need water that is suitable for consumption. Water that is fit for consumption is water that has been processed or without processing that has met the requirements and can be drunk immediately. Various factors can cause water quality to decline, one of which is a water container in the form of gallons of water. From the results of a survey of students, 69.2% of students stated that drinking water on campus was not adequate. Meanwhile, 16.9% stated that it was not suitable and 13.8% of the other students stated that drinking water was suitable for consumption. So that the control system is modified on the existing devices so that they can work more effectively and efficiently. Furthermore, the research data was taken using quantitative data analysis techniques with descriptive statistics and the calculation of the average relative error. In the resulting data, the relative error value of the working time variable is 0.51% and 17.2% of the variable delay. And the relative variable error value is 18.3%. For the level of particle content in water in gallon 1 an average of 54 mg / L with an average temperature of 27.44 ° C and in gallon 2 of 52.6 mg / L with an average temperature of 28 ° C.

Downloads

Download data is not yet available.

References

F. . Winarto, Manajemen Air Hujan: Sumber Baru Air Minum. Jakarta: PT Gramedia Pustaka Utama, 2016.

K. K. Indonesia, "PERMENKES No. 492/Th.2010 Tentang Persyaratan Kualitas Air Minum," Permenkes No. 492/Th.2010, no. 492. 2010.

K. K. Indonesia, "Keputusan Menteri Kesehatan Republik Indonesia Nomor 907/Menkes/Sk/VII/2002 Tentang Syarat-Syarat Dan Pengawasan Kualitas Air Minum," Keputusan Menteri Kesehat. Republik Indones., vol. 53, no. 9, pp. 1689-1699, 2002.

"Badan Pusat Statistik." https://www.bps.go.id/statictable/2009/02/20/1268/rata-rata-laju-pertumbuhan-penduduk-menurut-provinsi-1971---2019.html.

W. S. P. Imam Suhendra, "Aplikasi Load Cell Untuk Otomasi Pada Depot Air Minum Isi ulang," Sains dan Teknol., vol. 1, no. 1, pp. 11-19, 2015.

N. Prasojo, A. Setyo, Fajar, A. M. Rasyid., Paramitha, A. Desvi, Fauzi, M., "Rancang Bangun Alat Pembersih Galon Air Isi Ulang Berbasis Mikrokontroler," Tangerang, 2019.

S. P. Sakti, Pengantar Teknologi Sensor: Prinsip Dasar Sensor Besaran Mekanik. Malang: UB Press, 2017.

K. Manpreet and P. Jai, "Distance Measurement Of Object By Ultrasonic Sensor HC-SR04," IJSRD-International J. Sci. Res. Dev., vol. 3, no. 05, pp. 2321-0613, 2015, [Online]. Available: www.ijsrd.com.

Cytron Technologies, "Manual Book HC-SR04." pp. 1-10, 2013, [Online]. Available: http://raspoid.com/download/datasheet/HCSR04.

R. H. Sudhan, M. G. Kumar, A. U. Prakash, S. A. R. Devi, and S. P., "Arduino Atmega-328 Microcontroller," Ijireeice, vol. 3, no. 4, pp. 27-29, 2015, https://doi.org/10.17148/IJIREEICE.2015.3406

N. Anju Latha, B. Rama Murthy, and K. B. Kumar, "Distance Sensing with Ultrasonic Sensor and Arduino," Int. J. Adv. Res. Ideas Innov. Technol., vol. 2, no. 5, pp. 1-5, 2016.

J. P. A. Musawwirul Munir Syasmar, Lahming, "Modifikasi Alat Sortasi Gabah (Orizae Sativa L)," J. Pendidik. Teknol. Pertan., vol. 5, pp. 183-188, 2019, https://doi.org/10.32699/ppkm.v7i1.1060

B. H. I. Martalia Andayani, Widyaningrum Indrasari, "Kalibrasi Sensor Ultrasonik HC-SR04 Sebagai Sensor Pendeteksi Jarak Pada Ptotopie Sistem Peringatan Dini Bencana Banjir," Pros. Semin. Nas. Fis. SNF2016, vol. V, pp. SNF2016-CIP-61-SNF2016-CIP-66, 2016, https://doi.org/10.21009/0305020113

WHO (World Health Organization), "Total Dissolved Solids (TDS) in Drinking-Water," WHO/SDE/WSH/03.04/16. https://doi.org/10.1080/10417943609370625

A. Hasibuan, R. Rosdiana, and D. S. Tambunan, "Design and Development of An Automatic Door Gate Based on Internet of Things Using Arduino Uno", Bulletin of Comp. Sci. Electr. Eng., vol. 2, no. 1, pp. 17-27, Jun. 2021. https://doi.org/10.25008/bcsee.v2i1.1141

A. Hasibuan, Kartika, A. Qodri, and M. Isa, "Temperature Monitoring System using Arduino Uno and Smartphone Application", Bulletin of Comp. Sci. Electr. Eng., vol. 2, no. 2, Dec. 2021. https://doi.org/10.25008/bcsee.v2i2.1139

Downloads

Published

2021-12-28

How to Cite

Ramadhan, K., Mukti, L. H. ., Mahfudz, M. R. A. ., Rezaputra, M. D. D., & Hafizh, M. T. (2021). Modification of the Automatic Control System for Arduino ATmega 328P-Based Water Gallon Cleaner. Bulletin of Computer Science and Electrical Engineering, 2(2), 67–73. https://doi.org/10.25008/bcsee.v2i2.1131